2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet 1 of 15
020-100908-01 Rev. 1 (05-2012)
2.0kW/2.4kW/3.0kW Bare Bulb Replacement
Instruction Sheet
NOTICE: These instructions are for the relamping of the following lamp modules only.
INTRODUCTION
Use the following instructions when replacing the 2.0kW, 2.4kW and 3.0kW Xenon bulb in an existing
lamp module or new lamp house. This procedure involves disassembling the lamp house and replacing
the bulb inside. The entire lamp replacement procedure takes approximately one hour to complete.
Bare bulb replacement must be performed using the Christie approved
relamping jig (#38-804900-01). This jig is critical for lamp alignment. A lamp that is not properly
aligned can lower the brightness performance of the projector and cause overheating.
Complete all instructions carefully.
NOTE: Please refer to the Christie Website for detailed information regarding the Bare Bulb
warranty. Follow all instructions and warnings carefully. The warranty becomes void if the bulbs are
installed incorrectly.
Bulb Type Non-RoHS RoHS
2.0kW 03-000887-01P 003-000746-01
2.4kW 03-000883-01P 003-000744-01
3.0kW 003-000305 003-000305-02
Przeglądanie stron 0
1 2 3 4 5 6 ... 14 15

Podsumowanie treści

Strona 1 - Instruction Sheet

2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet 1 of 15020-100908-01 Rev. 1 (05-2012) 2.0kW/2.4kW/3.0kW Bare Bulb ReplacementInstruction S

Strona 2 - WARNINGS

10 of 15 2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet020-100908-01 Rev. 1 (05-2012)19. Remove the new bulb from its protective clamshel

Strona 3 - KITS REQUIRED

2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet 11 of 15020-100908-01 Rev. 1 (05-2012)23. Secure the anode lead to the side of the lamp h

Strona 4 - INSTRUCTIONS

12 of 15 2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet020-100908-01 Rev. 1 (05-2012)25. Loosen the 19 screws on the lamp mount for XYZ a

Strona 5

2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet 13 of 15020-100908-01 Rev. 1 (05-2012)27. With the lamp correctly positioned, tighten the

Strona 6 - Figure 5 – Place Lamp in Jig

14 of 15 2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet020-100908-01 Rev. 1 (05-2012)35. Position the retaining bar along the bottom edge

Strona 7 - Figure 8 – Install XYZ Stage

2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet 15 of 15020-100908-01 Rev. 1 (05-2012)For warranty claims carefully re-pack the bulb with

Strona 8 - Figure 9 – Adjust XYZ Stage

2 of 15 2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet020-100908-01 Rev. 1 (05-2012)WARNINGSLamp Replacement must be performed by QUALIFI

Strona 9 - Remove Old Lock Nut

2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet 3 of 15020-100908-01 Rev. 1 (05-2012)KITS REQUIREDEnsure the following components are ava

Strona 10 - Figure 14 - New Lock Nut

4 of 15 2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet020-100908-01 Rev. 1 (05-2012)INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING.

Strona 11

2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet 5 of 15020-100908-01 Rev. 1 (05-2012)6. Move the lamp module to a clean work surface for

Strona 12 - Figure 17 – Align Lamp

6 of 15 2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet020-100908-01 Rev. 1 (05-2012)8. Place the lamp house on the jig with the reflector

Strona 13 - LAMP INSTALLATION

2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet 7 of 15020-100908-01 Rev. 1 (05-2012)10. Lower the clamp on the jig to secure the lamp ho

Strona 14 - BULB DISPOSAL INSTRUCTIONS

8 of 15 2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet020-100908-01 Rev. 1 (05-2012)13. Adjust the XYZ stage until the three guidance hol

Strona 15

2.0kW/2.4kW/3.0kW Bare Bulb Replacement Instruction Sheet 9 of 15020-100908-01 Rev. 1 (05-2012)16. Holding the bulb from the front, unscrew and rem